MICROLIT BEATUS is a Bottle Top Dispenser (BTD) that offers a sophisticated blend of features and functionality. Built by our in-house team of product design engineers, it uses Springless Valveâ„¢, an award-winning technology, and Recirculation Valve for preventing loss of reagent during purging.
MICROLIT BEATUS also features two product innovations: EasyKnobâ„¢ and FlexiNozzleâ„¢ that enhance its ease of use and flexibility. Designed with ergonomics and intuitive handling in mind, it exhibits excellent chemical compatibility and helps in achieving precision with reliability in practical laboratory environments.
EasyKnobâ„¢ is a specially designed volume adjustment knob that allows 180° rotation for easy and
effortless volume setting.
The instrument is equipped with a PTFE Piston with an ETP O-Ring. It facilitates smooth and
effortless movement and ensures high chemical compatibility.
Recirculation Valve prevents the loss of reagents during purging
by re-directing them into the mounted bottle and facilitates bubble free dispensing.
MICROLIT BEATUS comes with an award-winning technology, Springless Valveâ„¢,
that facilitates smooth and jam-free functioning.
The instrument comes with FlexiNozzleâ„¢, an adjustable delivery nozzle.
It offers a high degree of flexibility, facilitating easy dispensing in demanding laboratory conditions.
A specially designed Adapter allows 360° rotation, facilitating
complete work flexibility.
MICROLIT BEATUS is calibrated in an ISO 17025 accredited
laboratory according to ISO 8655 standards. A calibration certificate is included inside the product package.
A calibration tool is also included for quick in-lab recalibration.
MICROLIT BEATUS is available in six unique volume ranges.
*Refer the table in technical specifications.
MICROLIT BEATUS is fully autoclavable at 121 °C and 15 psi
for a duration of 10-15 minutes.
Model No. | Vol. Range | Increment | Accuracy | CV | ||
---|---|---|---|---|---|---|
±% | ±ml | ±% | ±ml | |||
BEAT-2.5 | 0.25-2.5 ml | 0.05 ml | 0.6 | 0.015 | 0.2 | 0.005 |
BEAT-5 | 0.5-5 ml | 0.1 ml | 0.6 | 0.030 | 0.2 | 0.010 |
BEAT-10 | 1-10 ml | 0.2 ml | 0.6 | 0.060 | 0.2 | 0.020 |
BEAT-30 | 2.5-30 ml | 0.5 ml | 0.6 | 0.180 | 0.2 | 0.060 |
BEAT-60 | 5-60 ml | 1.0 ml | 0.6 | 0.360 | 0.2 | 0.120 |
BEAT-100 | 10-100 ml | 2.0 ml | 0.6 | 0.600 | 0.2 | 0.200 |
The error limits (Accuracy and Coefficient of Variation) mentioned above are in accordance
with the nominal capacity (or maximum volume) indicated on the instrument. These are obtained
by using the instrument with distilled water at equilibrium, the ambient temperature of 20 °C while operating
it smoothly and steadily. The error limits are in accordance with DIN EN ISO 8655-5.
![]() |